NAWI and MID Directives Explained for Marine Scale Buyers
The NAWI Directive 2014/31/EU covers non-automatic scales and is mandatory for regulated uses such as commercial transactions; the MID 2014/32/EU covers automatic weighing instruments where Member States prescribe them. Conforming instruments carry CE, a boxed M with the year and a notified body number. In-service verification is regulated nationally.
Two EU directives govern the metrological conformity of scales: Directive 2014/31/EU for non-automatic weighing instruments (NAWI) and Directive 2014/32/EU, the Measuring Instruments Directive (MID), whose Annex VIII covers automatic weighing instruments. Both have applied since 20 April 2016. This guide explains what each covers, what the CE and M markings mean, the role of notified bodies and when a marine scale needs this kind of conformity. This article is general information, not legal advice: check requirements for your use with your national fisheries control authority and national metrology authority.
The two directives at a glance
| NAWI Directive 2014/31/EU | MID 2014/32/EU (Annex VIII, MI-006) | |
|---|---|---|
| Covers | All non-automatic weighing instruments: an operator intervenes during weighing (Art. 1(1), 2(2)) | Automatic weighing instruments: catchweighers, checkweighers, weight labellers, gravimetric fillers, totalisers, rail-weighbridges |
| When conformity is mandatory | Always, for the regulated uses in Art. 1(2)(a)-(f) (Art. 3(2)) | Where a Member State prescribes the instrument for a measuring task (Art. 3, "optionality") |
| Marking | CE + M + year + notified body number (Arts 16-17) | CE + M + year + notified body number (Arts 21-22) |
| Conformity routes | B+D, B+F, D1 or F1 for simple mechanical instruments, or G (Art. 13) | For electronic systems or systems containing software: B+D, B+F, G or H1 (Annex VIII, Ch. I, point 4) |
| Replaced | Directive 2009/23/EC (Art. 45) | Directive 2004/22/EC |
OIML R 76 and R 51 cover the same instrument types at international level; how they compare is explained in OIML R51 vs R76.
Regulated uses under the NAWI Directive
The NAWI Directive applies to every non-automatic weighing instrument, but its requirements bite when the instrument is used for one of six categories in Article 1(2) of Directive 2014/31/EU:
- (a) determination of mass for commercial transactions;
- (b) calculation of a toll, tariff, tax, bonus, penalty, remuneration, indemnity or similar payment;
- (c) application of laws or regulations, or expert opinion in court proceedings;
- (d) weighing patients in medicine;
- (e) making up medicines and pharmacy or medical laboratory analyses;
- (f) determination of price on the basis of mass for direct sales to the public, and the making-up of prepackages.
Member States must ensure that instruments are not put into service for uses (a)-(f) unless they meet the Directive, and that they continue to conform in use (Article 3(2)-(3)). Everything else is category (g). Instruments for category (g) carry only the manufacturer's name and Max and must not bear the Directive's conformity marking (Annex III, point 2). If a regulated instrument is connected to a device not used for regulated purposes, that device carries the restrictive use symbol: a black capital M on a red square of at least 25 mm, crossed by two diagonals (Article 6(5), Annex III point 3).
CE and M marking: what to look for on the data plate
Metrological conformity is shown by the CE marking followed by the supplementary metrology marking: a capital letter M and the last two digits of the year of affixing, in a rectangle as high as the CE marking. It is followed by the identification number of the notified body involved in production control (NAWI Articles 16-17; MID Articles 21-22). An instrument can be subject to several EU acts (NAWI Article 14(3)), so a CE mark without the M rectangle does not show metrological conformity.
A NAWI used for regulated purposes must also carry these inscriptions (Annex III, point 1.1):
- EU-type examination certificate number, where appropriate;
- manufacturer's name or trade mark, and type, batch or serial number;
- accuracy class in an oval;
- Max, Min and verification scale interval e, also shown near the display (point 1.4);
- where applicable: d, tare limits T = +/- , Lim and special temperature limits.
Without a manufacturer's specification, the temperature range is -10 °C to +40 °C (Annex I, point 7.2), relevant for open decks and freezer holds.
Notified bodies and certificates
A notified body is a conformity assessment body designated by a Member State to carry out the third-party tasks in the modules, such as EU-type examination (Module B) or unit verification (Module G). NMi in the Netherlands, for example, is notified body 0122 under both the MID and the NAWI Directive. When comparing scales, ask for:
- the EU-type examination certificate and its scope, including accuracy class, temperature range and any conditions for use on moving platforms;
- the EU declaration of conformity (NAWI Article 14);
- evidence of the production-phase module and the notified body number on the instrument;
- the sealing plan, showing which adjustments are secured.
For instruments whose performance depends on gravity, conformity assessment must take into account gravity at the place of use or a defined gravity zone (NAWI Annex II, points 7.1-7.2), a real issue for vessels that fish at very different latitudes, as explained in gravity, latitude and calibration.
What "legal for trade" means in the EU
"Legal for trade" is an informal term that EU law does not use. In EU terms it usually means three things together:
- the instrument has passed conformity assessment under the NAWI Directive or, where prescribed, the MID, and carries CE, M and the notified body number;
- it is used within the limits on its data plate and certificate (class, Min, Max, temperature);
- it meets national in-service rules, such as periodic verification and intact seals, which WELMEC Guide 2 confirms are dealt with nationally.
A certificate for the type is not a guarantee that a specific installation is currently compliant: damage, broken seals or expired verification can change that. See calibration, verification and re-verification.
When is a conforming instrument required at sea?
| Use on board or at landing | Likely NAWI/MID relevance | Who decides |
|---|---|---|
| Weights that set the price at first sale | Commercial transaction, NAWI Art. 1(2)(a) | National law; buyer and authority |
| Weighing under Article 60 of the Control Regulation | Systems must be "approved, calibrated and sealed in accordance with national law" (Reg. 2026/1932 Art. 5) | Fisheries control authority, under national law |
| Prepackages labelled with nominal quantity | Making-up of prepackages, NAWI Art. 1(2)(f) | National metrology authority |
| Automatic grading or checkweighing sold by weight | MID MI-006 if prescribed nationally (MID Art. 3) | Member State |
| Internal yield control, crew information, most research sampling | Typically category (g), not regulated | Operator; research protocols may still require traceable calibration |
For the fisheries rules behind the second row, read EU Fisheries Control Regulation: weighing catches.
Motion, tilt and the essential requirements
NAWI Annex I, point 7.1 requires class II, III and IIII instruments liable to be used tilted to be sufficiently insensitive to the tilting that can occur in normal use. For automatic instruments, MID Annex VIII requires means to limit the effects of tilt, loading and rate of operation (Chapter I, point 3.1), and for instruments under special mechanical strain the manufacturer defines the mechanical conditions of use (point 1.3). WELMEC Guide 2:2023 section 2.3.1 translates this into test practice for NAWIs installed in ships, including acceleration compensation to at least ±3 m/s² and tilt tests up to 15°. Background on why this matters is in why ordinary scales fail at sea.
How WPL approaches this
WPL Industries holds NMi certificates EK-5417 and CE-284. Ask WPL which documents are available for the model and configuration you are considering, such as the M5 or M2, and confirm with your competent authority what your use requires. The legal metrology hub links all related guides.
Frequently asked questions
Does a CE mark on a scale mean it is approved for trade?
Not on its own. The CE mark can relate to other EU legislation. Metrological conformity under the NAWI Directive or MID is shown by the CE mark followed by the M rectangle with the year and the notified body number. Check the data plate for the accuracy class, Max, Min and e, and ask for the EU-type examination certificate.
Is the MID mandatory for automatic graders in every EU country?
No. Article 3 of the MID lets each Member State decide whether to prescribe measuring instruments, including automatic weighing instruments, for tasks such as fair trading or levying taxes. Where a Member State does not prescribe them, it must explain why. Check the national rules of the country where the grader is used.
Can a non-automatic scale be used for unregulated and regulated weighing at the same time?
Yes, but the instrument used for regulated purposes must conform to the NAWI Directive. Connected devices that are not used for regulated purposes, for example an extra display or printer, must carry the restrictive use symbol so that users do not rely on them, as required by Article 6(5) and Annex III.
What is a notified body number and where do I find it?
It is the four-digit identification number of the conformity assessment body involved in the production control phase, printed directly after the CE and M markings on the instrument or data plate. NMi in the Netherlands, for example, is notified body 0122 under both directives. The number lets authorities trace who assessed the instrument.
Sources
- Directive 2014/31/EU on non-automatic weighing instruments (NAWI Directive)
- Directive 2014/32/EU on measuring instruments (MID), Annex VIII MI-006 automatic weighing instruments
- WELMEC Guide 2:2023 Guide for NAWI, AWI and MDMI (Directives 2014/31/EU and 2014/32/EU), section 2.3.1 NAWIs installed in ships
- NMi: Accreditations and notified body status (notified body 0122)
- Commission Implementing Regulation (EU) 2026/1932 on the weighing of fishery products (OJ L, 11.8.2026)
- OIML R 76-1:2006 Non-automatic weighing instruments, Part 1: Metrological and technical requirements - Tests
Written and reviewed by WPL Industries weighing engineers. Technical and regulatory content is checked against the cited sources. Editorial policy